Metal Column Casing Performance Specification
Pendock’s metal casings system has been tested at the Welsh Technology Centre. (Report No. WL/PE/TN/G750312/1/2000/R), attaining UNION POUR L’AGREMENT for both hard and soft impacts.
Structural design performance was verified under the provisions of BS 5950: Part 6
Standards
Standards Table
| Description |
Code |
| Aluminium panel skins |
BS EN 485-2 |
Aluminium acoustic and thermal foam ”class O” core |
BS 1470 |
| Aluminium Support Frame |
BS 6082 |
| Stainless steel panel skins |
BS 1449 |
| Galvanised steel skins |
BS EN 10 147 |
| Fixing detail to panel skins |
BS 8200 |
| Panel fastenings |
BS 5427 |
| Adhesive |
BS 5380 |
Aluminium and Steel finishes achieve Class O when tested to BS 476 Part 6.
Due to its metal construction, the system can be treated as a non-combustible building element.
Our strict quality control system includes inspection sampling throughout the factory, backed up with random destruction tests.
Site Installation
Site work is kept to a minimum due to the unique design of the adjustable fixing arrangement integral within the carrier system.
Apart from primary fixing points to the structure, all other fixings utilize an adjustable nut insert that slides within the location channels of the carrier to the required fixing point. Panels and columns are then offered up and fixed to the carrier and where required, infill strips / gaskets are fitted within the joints.
Delivery
Casings are supplied to site with a protective film covering the outer skins. This can be stripped off when installation is successfully completed. Panels are supplied shrink wrapped on to pallets.
Carriers are supplied in bar lengths.
Components and fixings are boxed.